Chinese Diesel Heater Manuals and Troubleshooting E Code

The manual that came with my Chinese diesel heater was printed for ants and translated by someone having a long day. Here's the readable version: every fault code from E-01 to E-12, priming the fuel line, the timer, and both the LCD panel and the B2010 remote.

Share
Chinese Diesel Heater Manuals and Troubleshooting E Code

This is a tidied-up version of the manual that came with my Chinese diesel heater (the "12V–24V Common Digital Panel" – the five-button controller with the little LCD). The original is printed in a font size apparently chosen for ants, and translated by someone having a long day. Same information, just readable.

Heads-up: the LCD panel section covers pages 23–26 of the manual, and the B2010 section covers pages 31–34. The fault code table comes from the B2010 pages, but the numbering appears to be the same on both panels.

Jump to: Fault codes E-01 to E-12 · Most common faults · LCD panel settings · Priming the fuel line · B2010 panel and remote

Chinese diesel heater fault codes (E-01 to E-12)

If your panel is showing an E-code, here's what it means and what to check. These apply to both the five-button LCD panel and the B2010.

Code Fault What it means / what to check
E-01 Voltage too low Below 10V on a 12V system, or below 18V on a 24V system. Check your leisure battery and wiring.
E-02 Voltage too high Above 17V on a 12V system, or above 32V on a 24V system.
E-03 Glow plug fault The glow plug circuit is broken (open) or short-circuited.
E-04 Fuel pump fault The fuel pump circuit is broken (open) or short-circuited.
E-05 Overheating The heater casing is over 230°C. Check the air inlet and outlet aren't blocked.
E-06 Fan motor fault The fan circuit is broken or short-circuited, or the speed (Hall) sensor can't read the fan speed.
E-07 Disconnection The cable or plug between the control panel and the heater's controller is broken or loose. Check whether the blue communication wire is damaged or loose.
E-08 Flame went out Air in the fuel line, or a blockage, means the fuel supply is poor. Also check the casing temperature sensor isn't faulty, and that its socket terminal is making good contact.
E-09 Casing temperature sensor fault The sensor circuit is broken or short-circuited.
E-10 Ignition failure The heater failed to light twice. Check for a blocked fuel line, poor fuel flow, a stuck fuel pump or a clogged fuel filter.
E-11 Room temperature sensor fault The sensor circuit is broken or short-circuited.
E-12 Controller overheating The controller (ECU) is over 100°C. Check the air inlet and outlet aren't blocked, and whether the ECU is damaged.

The most common faults

  • E-08 (flame went out) – usually air in the fuel line. Prime the fuel line to push the air out, then try again.
  • E-10 (ignition failure) – the heater tried to light twice and gave up. Work through the fuel side: blocked line, poor flow, stuck pump, clogged filter.
  • E-01 (voltage too low) – your leisure battery is below 10V (12V system) or 18V (24V system). Charge it and check the wiring before blaming the heater.

The five-button LCD panel

The panel at a glance

The panel has an LCD screen, four indicator lights underneath it, and five buttons: Up, Set, On/Off, OK and Down.

Indicator lights

Light What it means
Status Solid when the heater is running. Blinks while it's shutting down. Goes off once shutdown is finished.
Time On when the screen is showing the clock, or when you're setting a timed start/stop.
Voltage On when the screen is showing voltage, or when you're changing a voltage-related setting.
Temperature On when the screen is showing the room temperature, or when you're setting the target temperature.

What the buttons do

Button Normal use While in settings
Up ▲ Raises the target temperature Increases the value you're changing
Down ▼ Lowers the target temperature Decreases the value you're changing
Set Enters the settings menu Exits without saving (careful – see below)
On/Off Short press: start the heater. Hold for 2 seconds: shut it down (Status light blinks while it cools down). –
OK Cycles through status screens (time, temperature, voltage, fault history) Confirms the current value and moves to the next setting

The settings menu

Press Set to enter the menu. You then step through the settings below in order. In each one, use Up/Down to change the value and OK to confirm and move on.

Important: when you've finished, you must press OK to save and exit. If you leave by pressing Set, nothing you changed is saved.
  1. Clock. Set the hour (24-hour format), press OK, set the minutes, press OK.
  2. Timed start/stop. Off by default (the screen shows "OF"). Press Up to switch it on ("on"), then press OK to set the first start/stop times and then the second start/stop times. Press OK again to move on. Full details in the timer section below.
  3. Admin password. To change the heater's settings you'll need to enter the 4-digit password. Use Up/Down to pick each digit and press OK to move to the next. After all four digits, press OK again. (The manual doesn't give the default password.)
  4. Fuel pump rate. Set the minimum pump rate and press OK, then the maximum pump rate and press OK. This controls how much fuel the heater burns at its lowest and highest settings.
  5. Fan speed. Set the minimum fan speed and press OK, then the maximum fan speed and press OK.
  6. Operating voltage. Choose between a 12V system (screen shows U-12) and a 24V system (U-24). This can only be changed while the heater is switched off. Before starting it up, make sure the fuel pump, fan motor and glow plug are all rated for the voltage you've picked, or you risk damaging them.
  7. Fan speed sensor type. Choose 1 if the fan's vane wheel has one magnet, or two magnets with opposite polarity. Choose 2 if it has two magnets with the same polarity. Get this wrong and the fan speed reading will be out by a factor of two. If you don't know, leave it at whatever it was set to from the factory.
  8. Change admin password. Shows "OFF" by default. Press OK to skip – your settings are saved and you exit the menu automatically. To change the password, press Up until it shows "ON", press OK, enter a new 4-digit password, and press OK again to save everything and exit.
Tip: if you change the password, write it down somewhere. You'll need it every time you want to change a setting.

Checking the heater's status

When you're not in the settings menu, press OK repeatedly to cycle through these screens:

  1. Time
  2. Room (ambient) temperature
  3. Target temperature (in automatic mode) or fuel pump rate (in manual mode)
  4. Supply voltage
  5. Fault history (previous error codes)

Then it loops back to the start.

Priming the fuel line

Useful on first install, after running out of fuel, or after an E-08 caused by air in the line.

  1. Make sure you're not in the settings menu.
  2. Press and hold Down, then press OK at the same time.
  3. When the screen shows H-OF, let go of OK first, then let go of Down.
  4. Press Up to start pumping. The screen shows H-ON and you'll hear the pump ticking.
  5. Press Down or Set to stop pumping and exit.

Timed start and stop

The timer lets you set up to two start/stop windows – handy for warming the van before you get up.

  1. In the settings menu, after setting the clock, press OK to reach the timer setting.
  2. It shows OF (off) by default. Press Up to switch it ON.
  3. Press OK and set the first window: start time (hour, then minute), then stop time (hour, then minute).
  4. Press OK and set the second window the same way. You can leave a gap between the two windows.
Note: the timer only runs once per setting. After both windows have run, the timer switches itself off and you'll need to go back in and set it again.

Switching temperature control mode

The heater has two modes: automatic and manual. To switch between them, make sure you're not in the settings menu, then press Up and Set at the same time. Each time you do this, it flips to the other mode, and the screen tells you which one you're in:

  • P- followed by a number (the fuel pump rate) means you're in manual mode.
  • A number followed by °C (the target temperature) means you're in automatic mode.

In both modes the heater still turns itself up and down as the temperature changes. The difference is how far up it's allowed to go:

Mode Screen shows How hard the heater can work
Automatic Target temperature, e.g. 22°C Anywhere from the minimum pump rate up to the maximum pump rate set in the settings menu. It can run at full power to reach your target.
Manual Pump rate, e.g. P-3.5 Anywhere from the minimum pump rate up to the rate you've chosen – never beyond it, even if the van is still cold.

In short: automatic mode lets the heater work as hard as it needs to, so it gets hotter. Manual mode puts a ceiling on it, which keeps the heat (and fuel use) within a range you've picked.


B2010 Diesel Heater Controller

The B2010 panel (with remote control)

Some of these heaters ship with a different controller instead: the B2010, a small black panel with a remote. It works differently from the five-button LCD panel above, so it gets its own section. For B2010 fault codes, see the fault code table at the top.

The B2010 buttons

The B2010 has five buttons: Setting and Confirm on the left of the screen, and Up, Power and Down on the right.

Button Heater off (standby) Heater running
Power Short press to switch on – the screen shows ON Long press to switch off – the screen shows OFF
Up Raises the temperature or power level Raises the temperature or power level
Down Lowers the temperature or power level Lowers the temperature or power level
Confirm Cycles through the status screens Cycles through the status screens
Setting Opens the settings Opens the settings

B2010 status screens

Press Confirm to step through these, one screen per press:

  1. Clock
  2. Room (ambient) temperature
  3. Supply voltage
  4. Power level or target temperature
  5. Casing temperature
  6. Fault code (only shown if there is a fault)

Switching between manual and automatic mode on the B2010

  • Manual mode runs the heater at a fixed power level. The screen shows something like P-01. This is the default.
  • Automatic mode holds the van at a target temperature. The screen shows that temperature flashing, for example 30°C.

To switch, press Up and Down together. Press them together again to switch back. This works whether the heater is on or off.

With the remote, while the heater is running: hold the remote's ON button for 3 seconds to switch modes. Wait at least 3 seconds before switching again.

Pairing the B2010 remote

  1. With the heater off, press Setting and Up together. The screen shows -PE-.
  2. Hold the ON/OFF button on the remote until it pairs.
  3. Once paired, it exits by itself, or you can press Power to exit. If you press nothing for 20 seconds, it exits anyway.

Priming the fuel line on the B2010

  1. With the heater off, press Setting and Down together. The screen shows a pumping time in seconds, for example 020.
  2. Press Setting to edit the number. Use Up to add time and Down to reduce it (maximum 999 seconds).
  3. Short press Confirm to start pumping. Short press it again to stop.
  4. Press Power to exit. If you press nothing for 20 seconds, it exits by itself.

The B2010 settings menu

With the heater off, long press Confirm/Setting to open the settings menu. You then go through these items in order:

  1. Clock. The screen shows 00:00 with the first digit flashing. Use Up/Down to set each digit and short press Confirm to move to the next digit. Short press Setting to move on to the next item.
  2. Timed start-up. Works the same way as the clock. Set the time you want the heater to switch on.
  3. Timed shutdown. Works the same way again. Set the time you want it to switch off.
  4. Password. The screen shows - - - - with the first digit flashing. Use Up/Down to change each digit and Confirm to move to the next. Once the password is correct, press Confirm to move on. (The manual doesn't give the default password.)
  5. Configuration code. A four-character code. Each character is one setting. Use Up/Down to change it and Confirm to move to the next:
Position Options What it sets
1st P = manual mode, T = automatic mode Default control mode
2nd 1 = 12V, 2 = 24V The voltage of the heater's parts (fuel pump, fan, glow plug)
3rd H = 5kW, L = 2kW Heater output
4th 2 = 22ml pump, 8 = 28ml pump, 1 = 16ml pump Fuel pump size
Note: the manual gives PHH2 as an example code, but that doesn't match its own table – the 2nd character should be 1 or 2. Going by the table, a 12V, 5kW heater with a 22ml pump in manual mode would be P1H2.
Important: when you've finished, press Power to save your settings and exit. If you wait for the menu to time out (20 seconds with no button press), nothing is saved.
Tip: the 2nd, 3rd and 4th characters must match the hardware you actually have. Picking the wrong voltage or pump size will cause poor running or damage. If you're not sure, leave them as they came from the factory.

B2010 screen timeout